Loading...
4120 Plumbing LicensingORDI'r idCE NO. 4120 (ruby. shed in the Salina Journal `_ 1931) i AN OKDINANCE providing for and relating to the construction, recon- % structien, r,pair, maintenance, use and inspection of gas pines and piping for natural or artificial gas, and the fittings, de- vices, appliances and connections appurtenant thereto, within the City of Salina, Kansas, requiring a license and bond of per- sons engaged in such work, and providing for the regulation thereof and providing penalties for the violation of said ordinance, and repealing ordinances No. 3078 and 3642, and Section 7 of Ordinance No. 2993. BE IT 0RD.,tR,ED by the Board of Commissioners of the City of Salina, Kansas: i Section 1. Flumbing Inspector Duties. The olumhing inspector have authority to and it shall be his duty to inspect and test all new installations and all extensions to or alterations of existing i gas-�-iping, and all fittings, devices, appliances and connections i appurtenant thereto, hereafter installed, and to inspect and test °,henever in his opinion it is necessary or pro!er, al existing installatinns of Eas tiiping and the fit'ings, devices, appliances i and connections appurtenant thereto in the City of Salina, Kansas, He shall enforce or cause to be enforced the provisions of this ordinance and for all purp-ses of this ordinance he shall have the right and authority during reasonable hours, and at any time Then in his opinion any emergency exists, to enter in or upon any build- ing or premises in the City of Salina for the purpose of making any inspection cr test and of performing any of the duties required of him b -NT this ordinance. '�,herever to this ordinance the wore inspector is used, it shall be deemed �o refer to the plumbing; inspector of the City of Salina, or his authorized assistant. Section 2. 1ermit Required. No building shall. hereafter be -Piped or fitted for gas, nor shall any repairs, alterations or extensions e made in any piping nor shall anv fittings or fixtures or aprliances be placed in any premises unless a permit therefore shall be granted i by the inspector, afte the filing v-ith him by the person intending i to do such work of an application describing the work to be done and the pr-mises in or uc-on which the same is to be done. much applica- tion shall state the correct location and the name and address of the owner of such �'uilding or premises, and a full and complete statement of the work oroposed to be done. Section 3. Inspection Notice. It shall be the duly of any per- son installing, al`,ering or changing any gels piping in any building or premises in the City of Salina to notify the inspec'or when the work is ready for inspection and the whole system of gas piping in - eluding the fittings, appliances, connections and apr,urtenances there- to, in or upon sue# building or premises shall be so arranged and con- nected as to enable the inspector properly to inspect and test the same. Section 4. License -Bond. No permit shall be issued to any erson to install, extend, repair, alter or connect any gas piping or gas appliances or appurtenances for the conveyance or use of natural or artificial gas in or upon any bulbing or premises in the City of Galina unless such person shall first secure from the City Clerk a license to engage in the occupation of gas fitter, -hich license shall be issued by the City Clerk upon the payment of a license or occupation tax of �1C.00 per year. Every such license shall expire on the 31st day of December after its date, and if issued after July lst, the license tax for the remainder of the year shall be one half of the amount above specified. Upon the filing by such applicant of an application for such license stating*, the name and business address of such applicant and such other pertinent information as the City Clerk may require, and upon the filing by such apNlicant with the City Clerk of a bond in the penal sum of �2000.0( executed by such principal and by a corporate surety duly i' authorized to do business as a surety of the State of Kansas, conditioned! 1 upon the good and faithful performance by such licensee of all work of the kind referred to in this ordinance in accordance with the require- ments and provisions of this ordinance and to indemnify said city and any and all persons for whom any such work may be done by such applicant against all damages rising from or caused by any o�;en trench work or other cause or by the carelessness or negligence of"such applicant or any of his agents, servants, or employees, in connection with any such work; t-kOVIDED 1I01�1 SEVER, that any person having a license to do plumbing ::ork, and v,ho has on deposit in the City 6lerk's office, and in effect', a plumber's bond as required by Ordinance No. 2981x, as amended by Ordinance No. 3201, as such ordinance nolo exist or as the,r­ay be here- after amended, shat; be ��ermitted to do any of the work mentioned in this ordinance to the same extent as if he had received a license and deposited his bond under this ordinance if such plumber's bond shall have endorsed thereon by the surety com,any by whom the same is is�I.ued, an endorsement providing for co,.rerage under the pro,,-isions of this ordinance and in the amount hereby required; provided further, that in any event a permit shall be secured for each niece of work as re- quired in this ordinance. licensee under this ordinance or the plumbing ordinance, doing any work mentioned in this ordinance, may do the same by his employees, but such licensee shall employ no person on any such work unless such Terson be fully qualified and experienced in such ­ork and such licensee shall be responsible for all of the acts, omissions or ne-ligence of any such employee in or about any such work and the bond of such licensee shall ocver the acts, omissions or negligence )f any such employee. i Section 5. Inspection Fees. Inspector shall collect a minimum j inspection fee of "'1.00 for each :'ermit issued b17 him under the : ro- visions of this ordinance, 1,hich shall cover Inspection fees for the orif7inal inspection of any system having not -core than six outlets or fixtures connected with such system, and shale_ collect additional inspection fees for on each original inspec`.ion of such system of 25�! for each additional outlet or fixture connected vrith such system, over six; and shall collect an additional fee of 50 cents for each `inspection on any premises after the original inspection, or for any inspection connected with the installation of fixtures on a system nov,T existing. Such inspection fees shall be paid to the inspector by the party filing the ap_;lication for a permit to do the work or installation to be covered by such inspecti^n, and shall be accounted for and paid by the inspector to the City Clerk. Section 6. Connection _:ith 1,9ins - Certificate. No person shall connect any gas piping system or installation, an inspection of ,' ch is required by the provisions of this ordinance, v-ith the gas mains operated by any gas distributing comr..,any in the City of Salina, here- inafter referred to as the gas company, nor shall any gas be turned into or used trough such gas piping system or installation, until the person connecting or turning on such gas shall receive a certificate from the inspector approving such installation. Section 7. Condemn and Disconnect 6 -stem. The Inspector may and it shall be his duty to condemn and disconnect or order discon- nected any connection of any such `as piping system or installation to any gas main whenever the person installing such has piping system shad have failed to comply with any of the provisions ^f this ordinance relating thereto, or v,henever in the opinion of the Inspector any gas slTstem or installation in any premises in the Ci_ttr of Sal'_na, Kansas is unsafe and liable to cause in;ury or damage to any person or property in said city. Section 8. Testing` All gas piping no,,' or hereafter installed or used in or on any premises in the Citi of Salina, shall ^rhenever any ins ,ection or test ti-lereof is made under the pro',TISions of this ordinance, be tested i�;ith an accurate pressure gauge of standard make by the inspector and shay be capable of �ithstanding pressure equal to fifteen pounds for a period of fifteen minutes. The person doing such ork shall furnish such gauge and shall leave the same connected until after th6- inspection and testing is completed. Section 9. _Rules and ,R ulations for all�vstems. All gas pi-oing and all appurtenances, appliances, fixtures or devices now or hereafter installed or used or designed for use in connection -ith the same in lipon or about any premises in the City of Salina shall be installed in accordance with, and shall conform to and be 7overned b-,, the folloti-ing rules, regulations and requirements, to-v,lt: (1) No person except the gas company or its authorized representa- tive shall turn the gas on or off at the meter, except gas mar be turned off Icy other in cases of emergency. (2) 1 -When the fitting ,job, and line testing has been apt -roved by the Inspector insofar as the same can be tested before the gas can be turned on, the meter shall be set and the gas shall be. turned on by the gas company or its authorized representative, and by no other per- son, after which such test shall be made by the Inspector as may be necessary. (3) :very gas heating device, :,ater heater, and the oven of every cooking device hereafter instal ed shall be quipped with good and suff'i- cient flue or vent connections through which unburned gas may flog., out of the premises, and no flue or vent used for such purpose shal be used for any purpose except as a flue or vent, and these regulations shall apply to existing systems or installations `rhen in the judgment of the Inspector the same is necessary to the safety of the occupant of said premises. (4) No solid damper shall be used in any flue pipe leading from any device -,,•here gas is consumed, and any damper used shall have a Y'.ole or holes of a diameter of not less than one fourth of the pipe diameter. (5) till gas outlets for the burning of any open gas flame shall be at least two and me half feet belol- any ceiling not fire proof, or other combustible material unles- pro erly protected by a metal shelf in which case such distance shall be not less than eighteen inches. (6) All outlets shall be securely fastened in place and properly capped. (7) In no case shall any split or broken fittings or pipe be used. (8) No cement or other substance shall be used to conceal, repair or cover any leaks, flaws or defects in pipes, fittings or connections. (9) leo gas pine shall be laid so as to support any w-ight, except small fixtures, or be subject to any strain, and the judgment of the Inspector in any such matter shall be conclusive. If, in the opinion of the Inspector, any such gas pipe is so laid as to be subject to any undue weight or strain, correcti-n thereof shall be made in such i manner as may be ordered by the Inspector. (10) All gas I;ipe installed beneath any ,foists or ceilings shall be securely strapped to the bottom of such foists or other secure f places with iron straps or pias hooks, and all gas pipes in any loca- tion shall be securely fastened to prevent salting or vibration. i (11). No fire test shall be made under any circumstances on any inside work. (12) A master valve shall be installed inside of the basement wall where a service pipe enters a basement and a valve shall also be installed on all furnace supply pipes at least four feet above the a. door, ,a e. (14) In no case shall any valve which shall need replacing from time to time'or vrhich may require inspection be placed under floors or between walls or in any inaccessible place. (15A All motor valves shalt be of the type that will close rhen electric current is of", unless other sufficient safety equipment is provided. In no case shall a lever handle gas control valve be con- °.necte5 �qIirect to a motor regulator. (17) he point of conn tion of any pi Qt light nip vrith any furnace fuel e shall be not s than four fe from the g opening i. or burner, and all ose hereafter i stalled shall b'� on the inle side of the master valve. (18) Every steam boiler having a gas fire shall be equipped with a low water cutout and a pressure limit control device, unless a regular experienced attendant is present and in charge of the same at all times. (19) No extension connection or fitting consisting in whole or in part of rubber or flexible tubing shall be used in connection with any gas burning appliance, and every such connecti^n shall be of rigid metal piping 7.7ith metal to metal joints, except when it is necessary to use gas in machine shoes for blo�,, torch purposes, or in laundry mangels, and in every such case t'r-ere shall be but one shut off valve i,­hich shal be located in the rigid pipe and in no case at the gas burning d; -vice or between the device and the rigid pipe. Section 10. All gas r)iping and all appliances, appurtenances and devices used or designed for use in connectim with the same hereafter installed in, on or about any premises in the City of Salina, shall be installed and shall be governed b, and conform to the following rules, i regulations and requirements, tp-wit: (1) No service pi; e from gas main to any meter shall be less than I one and one fourth inches in diameter. (2) No service pi. -:e from the meter to any hot air furnace or small boiler shall be less than one and one fourth inch in diameter. (3) No cast iron fitting shall be permitted or used. (4) all fitters installing any gas piping must leave an exact space for the meter and union for connections. (5) No gas shall be turned on until all pipes, connections, furnaces, stoves, burners and other appliances shal'_ have been inspected and approved by the i'lumbing Inspector. (6) No piping or fittings shall be covered or concealed from view until inspected, tested and approved by the Ilizmbing Inspector. (7) All drop or branch lines and oEenings for side brackets shall be of bracket ells or square bends where practicable, and unless other- wise sX,'ecially } ermitted by written permit obtained from the insx:ector no nipples shall be used in any side bracket lights. (S) In reducing pine sizes, nipples and reducing fittings must be used and in no casd shall bushings be used. (9) All pines shall be laid above timbers instead of beneath them if x,ossible. All piping must be reamed and free from obstnrtions. (10) No iointing material shall be placed in the female thread. (11) Unions must be of ground icints and must rot be used in concealed construction or places i.^rhich ar- not plainly visible, except inions on meters. (12) In disconnecting any appliances all openings in house l nes shall be car.T:ed tightly so as to prevent escape of gas, and this shall be done -)nly under the supervision of the Inspector, or by an authorized representative of the gas company, or by some person having a permit to do such work as required by this ordinance. (13) Steam or hot water piping connections on either high or lois pressure boilers, when necessary in connection with anv gas installa- tion, shall be made only by a licensed plumber. (14) Every hot water heating boiler shall be equipr;ed with a v'ater temperature control limiting device. (15) t1,11 steam or hot water boilers having lever handle control gas valves shall be connected with either diaphragm or water regulators. I Section 1;. Connections with IJiains-Meters. 10 person except the gas company or its authorized representative shall tap or make any connection z,ith any gas main, or any service pipe leading from any gas main to any meter, or shall change, alter or tamper with any r egulator or other device used for the purpose of regulating the gas pressure, or ,rith any gas meter. The gas company shall make and install all fittings to the meter and allservice pipes from the gas main to the pro:erty line, including a stop cock at the property line, and no other person shall connect or disconnect any fitting or piping on the inlet side of the meter, or connect or disconnect any gas meter except in case of emergency. I Section 12. Release Gas from Mains. No person other than a d1ily a,lthorized representative of the gas comp,-�ny shall at any time open an1T valve releasing gas from the mains of the company into any gas piping system in, or on any premises in the City of 6alna, and then only after such sTrstem has been approved in writing by the Inspector. Section 13. Shut Oft' Valves at Curb. The gas company shall not connect any gas main in the City of Salina, by means of a gas service pipe, with any premises in the City of Salina, w'thout installing on such Fas service pipe either at the curb line or at a point as near thereto as may be practicable, and in any event at a poirt cr s»ch gas service pipe before the same enters u -en private proierty, and at a point i^,hick is wholly unenclosed b�= any building or other strl.icture, a shut oft valve by means of which the gas may be shutoff or discon- nected from such premises, together with the necessary te,, box or valve box by means of w,-.ich access may be had to such shutoff valve, urless such shut off valve is located in an ^utside underground meter box having an easily removable manhole cover. It shall be unlalrrful for the gas company to permit any gas to flow from its gas mains to any premises in the City of Salina through any gas service pipe here- after installed unless such gas service pipe is eg1ii.px,ed -,Ylth a shut- off as hereinabove required, and it shall be unlawful for the gas company to Hermit any gas to flog* from its gas mains to any premises within the fire limits of the City of Salina, as now or hereafter established, through any gas service pipe no -.r- existing or hereafter installed, unless such gas s=rvice pi:e is eq ipped with a shut off valve as her,in provided. All shutoff valves so installed sl_.all be uniform and all tee boxes or valve boxes through which such shutoffs are beached unless located in an underground meter box as above provided for, shall be flush with the surface of the ground, pavement or side- ! walk where the same are installed and shall be plainly marked v,ith the word "gas" and a shut off key which shall fit all shut off valves with i i a handle sufficiently long to reach all 'alves so installed, shall be furnished to the fire department and to the Flumbing Inspector by the gas company. Section 14. Pipe Sizes. The following sizes of pipes shall be required in connection with tie installation of all heating, water heating or cooking devices or any gas piping or installation in one or two family dwelling houses or in com-rercial buildings, vh-re the total number of devices, to one meter, does not exceed one furnace and five additional fires, and rhere the maximum distance of any one of such fires from the meter does not exceed 50 feet, to -wit: Ir, all such buiic_ings equip:ed or to be equipped with a central heating rlant 14- inch pipe must be run from meter to heating plant or a full 11 inch connection left for heating plant. In all cases 1: inch pipe must be run from the meter to the in- side of the building. The following schedule applies in such buildings to all fires ^,ith the exception of central heating plant: One fire, use inch pipe. Two or three fires, use one inch pipe to first fire - 4 inch pipe to second and third fires; Four fires, use 14 inch pipe to first fire, one inch pipe to second fire and 4 inch pi -re to third and_ fourth fires. Hive fires, use 14 inch pipe to first and second fires, one inch pipe to third fire, and 4 inch to fourth and fifth fires. In cases of extreme long runs of pipe, the .:ipe size must be in- creased to such size as may be directed by the inspector. In all cases the pipe must be of sufficient si,e to carry the maximum installed ap,-licence capacities at one ounce pressure drop. ;Vhenever any gas piping sTrstem is installed which does r,ot come within the limits above specifically provided for, or which is installed in buildings or premises other than those above described, the sizes of the pipes used in such installation shall be such as are sufficiently large to properly supply the demand which may be used through such system, as the same may be determined from standard tables of pipe sizes in common use, and such as may be prescribed by the in- spector, and no such system.shall be installed until the pipe si,es to be used are aplroved by the Inspector. I Section 15. Inspection-tip�roval-Defective l'ork Removed. If, i upon inspection and. test by the Inspec`or the installation of any gas I piping or any part therf:of shall rhe found not to comply v.,ith the re- quirements of this ordinance, the same shall be changed, re -arranged, repaired or removed to conform to this ordinance and with the require- j -rents of the Inspector within such reasonable time as the inspector may deem necessary, not to exceed five days, and no gas shall be turned i on or permitted to floti: through any such piping or system until the same shall be inspected and approved by the Inspector, and any work or installation of an kind y or anypart thereof, which shall not or j cannot be repaired or changed to conform to this ordinance and to the I requirements of the Inspector, shall be immediately removed from any premises by the person installing the same and shall not at any time be used as a part of or in connection v,�ith the piping or distri?-'ution in of gas/or upon any such premises. Section 16. Record -Certificate. The Inspector shall keep a record of ali inspections of gas piping made by him and when the has piping system or installatior_ in or upon any premises, after inspection shall be found by him to comply with the requirements of this ordinance he shall issue to the party doing any such work, or to the owner of such premises, in duplicate, a certificate of satisfactory inspection, one copy of which shall be delivered to the gas company before gas is turned into such system. Section 17. Responsibility This ordinance shall not be con- strued to lessen the responsibility of any person o,,,ning, operating, controlling or installing any gas mains, service pipes, distribution pipes, connections, or gas fixtures, fittings or apuliances for damages caused to any person or property by any defect therein or by the acts or omissions, negligent or other�ise of any such person, or by any failure to comply with the z;rovisions of this ordinance, nor to re- lieve any such person from any such liability or responsibility,nor shall the City of Salina or any of its employees or agents be held as assuming any such liability or resxon sibility by reason of the inspectio authorized and required by this ordinance, or ry reason of any failure on the part of the city or any of its agents to make any such inspection or to discover any defect as a result of any inspection required by this ordinance, or on account of the failure of such city or any of its agents to enforce the provisions of this ordinance. I i Section 18. Any person who shall violate or fail to comply with any of the requirements of this ordinance or any requirements, ord,r j or direction of the i'lumbing Inspector given pursuant to this ordinance shall iii -on conviction be deemed guilty of a misdemeanor and upon con- viction shall be punished by fine of not less than �p25.00 nor more than X100.00, or by imprisonment not `o exceed 30 days or by both such fine and imprisonment, for each such offense. Section 19. yherever the term "person" is sued in this ordinance, it shall be deemed to apr,ly to any corporation, copartnership or associa- tion,, and to any officer, manager, member, agent, servant or representative thereof to the same extent as if each of such had been specifically men- tioned herein. Section 20. That Ordinances No. 3078 and 3642, and Section 7 of Ordinance 29939 of the Citlr of Salina be and the same are hereby re- pealed. Section 21. This ordinance shall take Pffect and be in force after its publication in the official citir pastier. Introduced, november 9th, 1931 i'assed, 1'ovember 16th, 1931 M. a. Stevenson Mav or Attest: _Chas. B. Banker - Ci_ty�lerk STATE' OF K"NS.,S j ) SS COUNTY OF SALINE ) I. Chas. E. Banner, City Clerk of the City of Salina, -L-ansas, do hereby certify that the above and foregoing is a true and correct coley of ordinance No. 4120 passed and approved by the Board of Commissioners of the City of Salina, November 16th, 1931; and a record of the vote on its final adox,tion is found on page + �5- { Jo1?rnal No. 12. City Clerk 12 (Published in the Salina Journal � � '�) 1931) ORDINANCE NO. 4120 AN ORDIAANCE providing for and relating to the construction, recon- struction, repair, maintenance, use and inspection of gas pipes and piping for natural or artificial gas, and the fittings, de- vices, appliances and connections appurtenant thereto, within the City of Salina, Kansas, requiring a license and bond of per- sons engaged in such work, and providing for the regulation thereof and providing penalties for the violation of said ordinance, and repealing Ordinances No. 3078 and 3642, and Section 7 of Ordinance No. 2993. BE IT ORDAINED by the Board of commissioners of the City of Salina, Kansas: Section 1. Plumbing Inspector Duties. The plumbing inspector have authority to and it shall be his duty to inspect and test all new installations and all extensions to or alterations of existing gas piping, and all fittings, devices, appliances and connections appurtenant thereto, hereafter installed, and to inspect and test whenever in his opinion it is necessary or proper, all existing installations of gas piping and the fittings, devices, applianced and connections ap1mrtenant thereto in the City of Salina, Kansas. He shall enforce or cause to be enforced the provisions of this ordinance and for all purposes of this ordinance he shall have the right and authority during reasonable hours, and at any time when in his opinion any emergency exists, to enter in or upon any building or premises in the City of Salina for the purpose of mak- ing any inspection or test and of performing any of the duties re- quired of him by this ordinance. Wherever in this ordinance the word inspector is used, it shall be deemed to refer to the plumb- ing inspector of the City of Salina, or his authorized assistant. Section 2. Permit Required. No building shall hereafter be piped or fitted for gas, nor shall any repairs, alterations or ex- tensions be made in any piping nor shall any fittings or fixtures or appliances be placed in any premises unless a permit therefore shall be granted by the inspector, after the filing with him by the person intending to do such work of an application describing the work to be done and the premises in or upon which the same is to be done. Such application shall state the correct location and the name and address of the owner of such building or premises, and a full and complete statement of the work proposed to be done. Section 3. Inspection Notice. It shall be the duty of any person installing, altering or changing any gas piping in any building or premises in the City of Salina to notify the inspector when the work is ready for inspection and the whole system of gas piping including the fittings, appliances, connections and appurten- ances thereto, in or upon such building or premises shall be so arranged and connected as to enable the inspector properly to in- spect and test the same. Section 4. License - Bond. No permit shall be issued to any person to install, extend, repair, alter or connect any gas piping or gas appliances or appurtenances for the conveyance or use of natural or artificial'..gas in or upon any building or premises in the Dity of Salina unless such person shall first secure from the City Clerk a license to engage in the occupation of gas fitter, which license shall be issued by the City Clerk upon the payment of a license or occupation tax of $10.00 per year. Every such. license shall expire on the 31st day of December after its date, and if issued after July 1st, the license tax for the remainder of the year shall be one half of the amount above specified. Upon the filing by such applicant of an application for such license stating the name and business address of such applicant and such other per- tinent information as the City Clerk may require, and upon the filing by such applicant with the City Clerk of a bond in the penal sum of $2000.00 executed by such principal and by a corporate surety duly authorized to do business as a surety of the State of Kansas, con- ditioned upon the good and faithful,performance by such licensee of all work of the kind referred to in this ordinance in accordance with the requirements and provisions of this ordinance and to indemnify said city and any and all persons for whom any such work may be done by such applicant against all damages rising from or caused by any open trench work or other cause or by the carelessness or negligence of such applicant or any of his agents, servants, or employees, in connection with any such work; Provided however, that any person having a license to do plumbing work, and who has on deposit in the City Clerk's office, and in effect, a plumber's bond as required by Ordinance No. 2980, as amended by Ordinance No. 3201, as such ordin- ance now exist or as they may be hereafter amended, shall be per- mitted to do any of the work mentioned in this ordinance to the same extent as if he had received a license and deposited his bond under this ordinance if such plumber's bond shall have endorsed thereon by the surety company by whom the same is issued, an endoi�e- ment providing for coverage under the provisions of this ordinance and in the amount hereby required; provided further that in any event a permit shall be secured for each piece of work as required in this ordinance. A licensee under this ordinance or the plumbing ordinance, doing any work mentioned in this ordinance, may do the same by his employees, but such licensee shall employ no person on any such work unless such person be fully qualified and experienced in such work and such licensee shall be responsible for all of the acts, omissions or negligence of any such employee in or about any such work and the bond of such licensee shall cover the acts, omissions or negligences of any such employee. Section 5. Inspection Fees. Inspector shall collect a minimum inspection fee of $1.00 for each permit issued by him under the pro- visions of this ordinance, which shall cover inspection fees for the original inspection of any system having not more than six outlets or fixtures connected with such system, and shall collect additional inspection fees for on each original inspection of such system of 25� for each additional outlet or fixture connected with such system, over six; and shall collect an additional fee of 50 cents for each inspection on any premises after the original inspection, or for any inspection connected with the installation of fixtures on a system now existing. Such inspection fees shall be paid to the inspector by the party filing the application for a permit to do the work or installation to be covered by such inspection, and shall be accounted for and paid by the inspector to the City Clerk. Section 6. Connection with Mains - Certificate. No person shall connect any gas piping system or installation, an inspection of which is required by the provisions of this ordinance, with the gas mains operated by any gas distributing company in the City of Salina, hereinafter referred to as the gas company, nor shall any gas be turned into or used through such gas piping system or in- stallation, until the person connecting or turning on such gas shall receive a certificate from the inspector approving such in- stallation. Section 7. Condemn and Disconnect lystem.. The Inspector may and it shall be his duty to condemn and disconnect or order disconnected any connection of any such gas piping system or in- stallation to any gas main whenever the person installing such gas piping system shall have failed to comply with any of the provisions of this ordinance relating thereto, or whenever in the opinion of the Inspector any gas piping system or installation in any premises in the City of Salina, Kansas is unsafe and liable to cause injury or damage to any person or property in said city. Sedtion 8. TestinA . All gas piping now or hereafter installed or used in or on any premises in the City of Salina, shall whenever any inspection or test thereof is made under the provisions of this ordinance, be tested Lith an accurate pressure gauge of standard make by the Inspector and shall be capable of withstanding pressure equal to fifteen pounds for a period of fifteen minutes. The person doing such work shall furnish such gauge and shall leave the same connected until after the inspection and testing is completed. Section 9. Rules and Regulations for all Systems. All gas piping and all appurtenances, appliances, fixtures or devices now or hereafter installed or used or designed for use in connection with the same in upon or about any premises in the City of Salina shall be installed in accordance with, and shall conform to and be governed by the following rules, regulations and requirements, to -wit: (1) No person except the gas company or its authorized representative shall turn the gas on or off at the meter, except gas may be turned off by other in cases of emergency. (2) When the fitting ,job, and line testing has been approved by the Inspector insofar as the same can be tested before the gas can be turned on, the meter shall be set and the gas shall be turned on by the gas company or its authorized representative, and by no other person, after which such test shall be made by the Inspector as may be necessary. (3) Every gas heating device, water heater, and the oven of every cooking device hereafter installed shall be equipped with good and sufficient flue or vent connections through which unburned gas may flow out of the premises, and no flue or vent used for such purpose shall be used for any purpose except as a flue or vent, and these regulations shall apply to existing systems or installations when in the judgment of the Inspector the same is necessary to the safety of the occupant of said premises. (4) No solid damper shall be used in any flue pipe leading from any device where gas is consumed, and any damper used shall have a hole or holes of a diameter of not less than one fourth of the pipe diameter. (5) all gas outlets for the burning of any open gas flame shall be at least two and one half feet below any ceiling not fire proof, or other combustible material unless properly protected by a metal shelf in which case such distance shall be not less than eighteen inches. (6) All 6utlets shall be securely fastened in place and properly capped. (7) In no case shall any split or broken fittings or pipe be used. (8) No cement or other substance shall be used to conceal, repair or cover any leaks, flaws or defects in pipes, fittings or connections. (9) No gas pipe shall be laid so as to support any weight, except small fixtures, or be subject to any strain, and the judgment of the Inspector in any such matter shall be conclusive. If, in the opinion of the Inspector, any such gas pipe is so laid as to be subject to any undue weight or strain, correction thereof shall be made in such manner as may be ordered by the Inspector. (10) I'll gas pipe installed beneath any ,joists or ceilings shall be securely strapped to the bottom of such joists or other secure places with iron straps or gas hooks, and all gas pipes in any location shall be securely fastened to prevent sagging or Vibration. (11) No fire test shall be made under any circumstances on any inside work. (12) A master valve shall be installed inside of the base- ment wall where a service pipe enters a basement and a valve shall also be installed on all furnace supply pipes at least four feet above the floor. t� �.:... ���.:.:�(.,73,)`�'�--•�'ves=u:s:eel=i:n=gas=gi�3:n�shsll_he=o-�e=�r_aund (14) In no case shall any valve which shall need replacing from time to time or which may require inspection be placed under floors or between walls or in any inaccessible place. (15). All motor valves shall be of the type that will close when electric current is off, unless other sufficient safety equip- ment is provided. (16) In no case shall a lever handle gas control valve be connected direct to a motor regulator. Tli�he point of connection of an pilot ight p\sha h a n /^ `any`furna a-4-:uK li e s be no \less th four et e gas�,openi or ti�irner„ and 1 those , ereafte instal` be on the inlet de oof the master valve. (18) Every steam boiler having a gas fire shall be equipped with a low water cutout and a pressure limit control device, unless a regular, experienced attendant is present and in charge of the same at all times. (19) No extension connection or fitting consisting in whole or in part of rubber or flexible tubing shall be used in connection with any gas burning appliance, and every such connection shall be of rigid metal piping with metal to metal joints, except when it is necessary to use gas in machine shops for blow torch purposes, or in laundry mangels, and in every such case there shall be but one shut off valve which shall be located in the rigid pipe and in no case at the gas burning device or between the device and the rigid pipe. Section 10, all gas piping,and all appliances, appurtenances and devices used or designed for use in connection with the same hereafter installed in, on or about any premises in the City of Salina, shall be installed and shall be governed by and conform to the following rules, regulations and requirements to --pit: (1) No service pipe from gas main to any meter shall be less than one and one fourth inches in diameter. (2) No servicd pipe from the meter to any hot air furnace or small boiler shall be less than one and one fourth inch in diameter. (3) No cast iron fitting shall be permitted or used. (4) all fitters installing any gas piping must leave an exact space for the meter and union for connections. (5) No gas shall be turned on until all pipes, connections, furnaces, stoves, burners and other appliances shall have been inspected and approved by the Plumbing Inspector. (6) No piping or fittings shall be covered or concealed from view until inspected, tested and approved by the Plumbing Inspector. (7) All drop or branch lines and openings for side brackets shall be of bracket ells or square bends where practicable, and unless otherwise specially permitted by written permit obtained from the inspector no nipples shall be used in any side bracket lights. (8) In reducing pipe sizes, nipples and reducing fittings must be used and in no case shall bushings be used. (9) All pipes shall be laid above timbers instead of beneath them if possible. All piping must be reamed and free from obstruc- tions. (10) No jointing material shall be placed in the female thread. (11) Unions must be of ground joints and must not be used in concealed construction or places which are not plainly visible, ex- cept unions on meters. (12) In disconnecting any appliances all openingsin house lines shall be capped tightly so as to prevent escape of gas, and this shall be done only under the supervision of the Inspector, or by an authorized representative of the gas company, or by some person having a permit to do such work as required by this ordinance. (13) Steam or hot water piping connections on either high or low pressure boilers, when necessary in connection with any gas installation, shall be made only by a licensed plumber. (14) Every hot water heating boiler shall be equipped with a water temperature control limiting device. (15) "11 steam or hot water boilers having lever handle con- trol gas valves shall be connected with eit#er diaphragm or water regulators. Section 11. connections with Mains -Meters. No person except the gas company or its authorized representative shall tap or make any connection with,any gas main, or any service pipe leading from any gas main to any -meter, or shall change, alter or tamper with any regulator or other device used for the purpose of regulating the gas pressure, or with any gas meter. The gas company shall make and install all fittings to the meter and all service pipes from the gas main to the property line, including a stop cock at the property line, and no other person shall connect or disconnect any fitting or piping on the inlet side of the meter, or connect or disconnect any gas meter except in case of emergency. Section 12. Release Gas from Mains. No person other than a duly authorized representative of the gas company shall at any time open any valve releasing gas from the mains of the company into any gas piping system in, or on any premises in the City of Salina, and then only after such system has been approved in writing by the Inspector. Section 13. Shut Off Valves at Curb. The gas company shall not connect any gas main in the City of Salina, by means of a gas service pipe, with any premises in the City of Salina, without installing on such gas se:^viae pipe either at the curb line or at a point as near thereto as may be practicable, and in any event at a point on such gas service pipe before the same enters upon private property, and at a point which is wholly unenclosed by any building or other structure, a shut off valve by means of which the gas may be shutoff or disconnected from such premises, together with the necessary tee box or valve box by means.of which access may be had to such shutoff valve, unless such shut off valve is located in an outside underground meter box having an easily removable man- hole cover. It shall be unlawful for the gas company to permit any gas to flow from its gas mains to any premises in the City of Salina through any gas service pipe hereafter installed unless such gas service pipe is equipped with a shutoff valve as hereinabove re- quired, and it shall be unlawful for the gas company to permit any gas to flow from its gas mains to any premises within the fire limits of the City of Salina, as now or hereafter established, through any gas service pipe now existing or hereafter installed, unless such gas service pipe is equipped with a shut off valve as herein provided. All shutoff valves so installed shall be uniform and all tee boxes or valve boxes through which such shutoffs are reached unless located in an underground meter box as above pro- vided for, shall be flush with the surface of the ground, pavement or sidewalk where the same are installed and shall be plainly marked with the word "gas" and a shut off key which shall fit all shut off valves with a handle sufficiently long to reach all valves so installed, shall'be furnished to the fire department and to the Plumbing Inspector by the gas company. Section 14. Pipe Sizes. cl'he following sizes of pipes shall be required in connection with the installation of all heating, water heating or cooking devices on any gas piping or installation in one or two family dwelling houses or in commercial buildings, where the total number of devicds, to one meter, does not exceed .one furnace and five additional fires, and where the maximum dis- tance of any one of such fires from the meter does not exceed 50 feet, to -wit: In all such buildings equipped or to be equipped wit7g a central heating plant 14 inch pipe must be run from meter to heating plant or a full 14 inch connection left for heating plant. In all cases 14 inch pipe must be run from the meter to the inside of the building. The following schedule applies in such buildings to all fires with the exception of central heating plant: One fire, use j inch pipe. Two or three fires, use one inch pipe to first fire; 3 inch pipe to second and third fires. Four fires, use 14 inch pipe to first fire, one inch pipe to second fire and 4 inch pipe to third and fourth fires. Five fires, use 14 inch pipe to first and second fires, one inch pipe to third fire, and 4 inch to fourth and fifth fires. In cases of extreme long runs of pipe, the pipe size must be increased to such size as may be directed by the inspector. In all cases the pipe must be of sufficient size to carry the maximum installed appliance capacities at one ounce pressure drop. Whenever any gas piping system is installed which does not come within the limits above specifically provided for, or which is installed in buildings or premises other than those above de- scribed, the sizes of the pipes used in such installation shall be such as are sufficiently large to properly supply the demand which may be used through such system, as the same may be determined from standard tables of pipe sizes in common use, and such as may be pre- scribed by the inspector, and no such system shall be installed until the pipe sizes to be used are approved by the Inspector. Section 15. Inspection -Approval -Defective York Removed. If, upon inspection and test by the Inspector the installation of any gas piping or any part thereof shall be found not to comply with the requirements of this ordinance, the same shall be changed, re -arranged, repaired or removed to conform to this ordinance and with the require- ments of the Inspector within such reasonable time as.the Inspector may deem necessary, not to exceed five days, and no gas shall be turned on or permitted to flow through any such piping or system until the same shall be inspected and approved by the Inspector, and any work or installation of any kind or any part thereof, which shall not or cannot be repaired or changed to conform to this ordinance and to the requirements of the inspector, shall be immediately removed from any premises by the person installing the same and shall not at any time be used as a part of or in connection with the piping or distribution of gas in or upon any such premises. Section 16. Record -Certificate The Inspector shall keep a record of all inspections of gas piping made by him and when the gas piping system or installation in or upon any premises, after inspection shall be found by him to comply with the requirements of this ordinance, he shall issue to the party doing any such work, or to the owner of such premises, in duplicate, a certificate of satisfactory inspection, one copy of which shall be delivered to the gas company before gas is.turned into such system. Section 17. Responsibility This ordinance shall not be con- strued to lessen the responsibility of any person owning, operating, controlling or installing any gas mains, service pipes, distribution pipes, connections, or gas fixtures, fittings or appliances for damages caused to any person or property by any defect therein or b7 the acts or omissions, negligent or otherwise of any such person, or by any failure to comply with the provisions of this ordinance, nor to relieve any such person from any such liability or responsi- bility, nor shall the City of Salina or any of its employees or agents be held as assuming any such liability or responsibility by reason of the inspection authorized and required by this ordinance, or by reason of any failure on the part of the city or any of its agents to make any such inspection or to discover any defect as a result of any inspection required by this ordinance, or on account of the failure of such city or any of its agents to enforce the provisions of this ordinance. Section 18. Any person who shall violate or fail to comply with any of the requirements of this ordinance or any requirements, order or direction of the Plumbing Inspector given pursuant to this ordinance shall upon conviction be deemed guilty of a misdemeanor and upon conviction shall be punished by fine of not less than $25.00 nor more than 4100.00, or by imprisonment not to exceed 30 days or by both such fine and imprisonment, for each such offense. Section 191 Wherever the term "person° is used in this ordinance, it shall be deemed to apply to any corporation, co- partnership or association, and to any officer, manager, member, agent, servant or representative thereof to the same extent as if each of such had been specifically mentioned herein. Section 20. That Ordinances No. 3078 and 3642, and Section 7 of Ordinance 2993,- of the City of Salina be and the same are hereby repealed. Section 21. This ordinance shall take effect and be in force after its publication in the official city paper. Introduced, November 9th, 1931 Passed, November 16th, 1931 -A/-' 9. a I Mayo r Attest: City Clerk