Loading...
16-10848 Amending Chapter 8, Article I, Division 3 Adopting 2012 Unifrom Plumbing Code(Summary published in The Salina Journal on October, _ 2016) '1 (Published on the City of Salina's website for a minimum of one week from October LL to 2016) ORDINANCE NUMBER 16-10848 AN ORDINANCE AMENDING CHAPTER 8, ARTICLE I, DIVISION 3 OF THE SALINA CODE BY REPEALING THE EXISTING SECTIONS 8-71 THROUGH 8-118; ADOPTING w THE 2012 EDITION OF THE UNIFOIUNI PLUMBING CODE BY REFERENCE; AND = ADOPTING LOCAL AMENDMENTS. 0 BE IT ORDAINED by the Governing Body of the City of Salina, Kansas: Section 1. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article I. Division 3 to be numbered 8-1-3-1 which section reads as follows: Sec.8-1-3-1. Uniform Plumbing Code adopted. The Uniform Plumbing Code, 2012 Edition, promulgated and published by the Intemation Association of Plumbing and Mechanical Officials, not including any of its appendice (UPC) is adopted and incorporated by reference, except as amended in this division. Section 2. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article 1. Division 3 to be numbered 8-1-3-101.1 which section reads as follows: Sec. 8-1-3-101.1 Amendment to Section 101.1 of the UPC. Section 101.1 of the UPC is amended to read as follows: See. 101.1 Title. These regulations shall be known as the Uniform Plumbing Code of the City of Salina. Kansas, hereinafter referred to as the "UPC" or "plumbing code". Section 3. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article I. Division 3 to be numbered 8-1-3-102.1 which section reads as follows: Sec. 8-1-3-102.1 Amendment to Section 102.1 of the UPC. Section 102.1 of the UPC is amended to read as follows: Sec. 102.1 Authority Having Jurisdiction. The authority having jurisdiction shall be the building official. The city manager shall appoint and hereby delegates to the building official and any other city employees in designated technical roles the authority necessary to administer, interpret, and enforce this code. The building official shall have the authority to adopt and enforce rules and regulations supplemental to and consistent with this code. Section 4. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article I, Division 3 to be numbered 8-1-3-102.3 which section reads as follows: Section 8-1-3-102.3 Amendment to Section 102.3 of the UPC. Section 102.3 of the UPC is amended to read as follows: Sec. 102.3 Board of Appeals. The building advisory board shall hear and decide y appeals of orders; decisions or determinations made by the building official relative to the application and interpretation of this code. (See Article II.) Section 4. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article I, Division 3 to be numbered 8-1-3-103.1.1 which section reads as follows: Sec. 8-1-3-103.1.1 Amendment to Section 103.1.1 of the UPC. Section 103.1.1 of the UPC is amended to read as follows Sec. 103.1.1 Exempt Work. A permit shall not be required for the following: 1. The stopping of leaks in drains, soil, waste or vent pipe, provided however, that a trap, drain pipe, soil waste, or vent pipe become defective and it becomes necessary to remove and replace the same with new material, the same shall be considered as new work and a permit shall be procured and inspection made as provided in this code. 2. The clearing of stoppages, including the removal and reinstallation of water closets, or the repairing of leaks in pipes, valves or fixtures, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes, or fixtures. Exemptions from the permit requirements of this code shall not be deemed to grant authorization for work to be done in violation of the provisions of the code or other laws and ordinances of this jurisdiction. Section 5. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article 1, Division 3 to be numbered 8-1-3-103.4.1 which section reads as follows: Sec. 8-1-3-103.4.1 Amendment to Section 103.4.1 of the UPC. Section 103.1.1 of the UPC is amended to read as follows: Sec. 103.4.1 Permit Fees. The fee for each permit shall be as set forth in the fee schedule adopted pursuant to Section 2-2 of the Salina Code. Section 6. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article I. Division 3 to be numbered 8-1-3-103.4.2 which section reads as follows: Sec. 8-1-3-103.4.2 Amendment to Section 103.4.2 of the UPC. Section 103.4.2 of the UPC is amended to read as follows: Sec. 103.4.2 Plan Review Fees. No fees shall be charged for plan review. Section 7. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article I, Division 3 to be numbered 8-1-3-312.6 which section reads as follows: Sec. 8-1-3-312.6 Amendment to Section 312.6 of the UPC. n n Section 312.6 of the UPC is amended to read as follows: Sec. 312.6 Freezing Protection. No water, soil, or waste pipes shall be installed or permitted outside of a building or in an exterior wall, unless where necessary, adequate provisions are made to protect such pipe from freezing by insulation or heat, or both. Exterior water supply system piping shall be installed not less than 6 inches below the y frost line. The frost line depth in the city is 36 inches. 8 4 0 g II Section 8. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article 1. Division 3 to be numbered 8-1-3-316.1 which section reads as follows Sec. 8-1-3-316 Amendment to Section 316.1 of the UPC. Section 316.1 of the UPC is amended to read as follows: Sec. 8-1-3-316.1 Increasers and Reducers. Where different sizes of pipes or pipes and fittings are to be connected, the proper size increasers or reducers or reducing fittings shall be used between the two sizes. Bushings are approved fittings for this purpose in vent piping and as increasers in drainage piping. Brass or cast iron body cleanouts shall not be used as a reducer or adapter from cast iron drainage pipe to iron pipe size (IPS) pipe. Section 9. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article 1. Division 3 to be numbered 8 -1 -3 -Table 422.1 which section reads as follows: Sec. 8-1-3-422.1 Amendment to Table 422.1 of the UPC. Table 422.1 of the UPC is amended to read as follows: TABLE 422.1 MINIMUM PLUMBING FACILITIES (1) Each building shall be provided with sanitary facilities, including provisions for persons with disabilities as described by the 2010 ADA Standards for Accessible Design. Table 422.1 applies to new buildings, additions to a building, and changes of occupancy or type in an existing building resulting in an increased occupant load. Tv Oc a of u ancv 2 Water closets Urinals (Fixtures per Lavatories (fixtures per Bathtubs or Drinking fountains / Other (fixtures per showers facilities (fixtures person)(3) person)(4) person) (5),(6) (fixtures per person) perperson) A- Assembly Male- I: 1-200 Male: 1: 1-250 1 service (fi) dor 1:1-100 2:201-300 1:1-200 2:251-500 sink or 0 per anent 2:101-200 3:301-400 2:201-400 3:501-750 laundrvtr ' sea ng) -theaters, 3:201-400 4:401-600 3:401-600 syn hony and Female- 4: 601-750 Over 750, add (1) con ert halls, 1:1-25 Over 600 Female: fixture for each aud toriums 2:26-50 add (1) 1:1-100 additional 500 3:51-100 fixture for 2: 101-200 persons. 4:101-200 each 4:201-300 6:201-300 additional 5:301-500 8: 301400 300 males. 6: 501-750 Over 400 add Over 750, add (1) fixture for (1) fixture for each additional each additional 250 males and 250 males and (1) fixture for (1) fixture for each 125 each 200 females. females. A- Assembly Male- l: 1-200 Male: _ 1: 1-250 1 service (re aurants,pubs, 1:1-50 2:201-300 l:1-150 2:251-500 sink or lou ges, night 2: 51-150 3: 301-400 2: 151-200 3: 501-750 laundry clu s.casinos and 3: 151-300 4:401-600 3: 201400 bar luet halls) 4: 301-400 Female: Over 750, add (1) Female- Over 600 1: 1-150 fixture for each I: 1-25 add (1) 2: 151-200 additional 500 2: 26-50 fixture for 4: 201400 persons. 3:51-100 each 4:101-200 additional Over 400, add 6: 201-300 300 males. (1) fixture for 8: 301-400 each additional 250 males and Over 400 add (1) fixture for (1) fixture for each additional each additional 200 females. 250 males and (1) fixture for each 125 females. Tv a of Water closets Urinals Lavatories Bathtubs or Drinking fountains / Other (fixtures per showers facilities (fixtures Oc u ancv 2 (Fixtures per (fixtures per person)(3) person)(4) person) (5),(6) (fixtures per person) perperson) A- Assembly Male- 1: 1-100 Males: _ 1: 1-250 1 service (wiihout fixed or 1:1-100 2: 101-200 1: 1-200 2: 251-500 sink or u pe anent 2:101-200 3:201-400 2:201-400 3:501-750 laundrytr sea g) -arcades, 3:201-300 4:401-600 3:401-600 art llery, 4:601-750 bov ling alley, pla sof worship, mu urns, Female- Over 600. Females: Over 750, add (1) libr ries, lecture 1:1-25 add (1) 1: 1-100 fixture for each hal , courtrooms, 2: 26-50 fixture for 2: 101-200 additional 500 gy asiums(with 3:51-100 each 4:201-300 persons. out pectator 4: 101-200 additional 5:301-500 sea g), indoor 6: 201-300 300 males. 6: 501-750 po s(without 8:301-400 spe ator seating), Over 750, add ind or tennis Over 400, add (1) fixture for co (without (1) fixture for each additional spe tator seating) each additional 250 males and 500 males and (1) fixture for (1) fixture for each additional each additional 200 females. 125 females. A- Assembly Male- 1: 1-100 Male- _ 1: 1-250 1 service (iru Dor activities 1:1-100 2:101-200 1:1-200 2:251-500 sink or or inning events 2:101-200 3:201-400 2:201-400 3:501-750 laundry tr,, wit spectator 3:201-400 4:401-600 3:401-750 sea ng)- Female- Female- Over 750 add (1) sw ming pools, I: 1-25 Over 600, I: 1-100 fixture for each sk ing rinks, 2:26-50 add (1) 2: 101-200 additional 500 ten is coons, 3: 51-100 fixture for 4: 201-300 persons. are as and 4: 101-200 each 5: 301-500 gyr nasiums. 6:201-300 additional 6:501-750 8: 301400 300 males. Over 750, add Over 400, add (1) fixture for (1) fixture for each additional each additional 250 males and 500 males and (1) fixture for (1) fixture for each additional each additional 200 females. 125 females. Ty a of Water closets Urinals (4) Lavatories Bathtubs or Drinking fountains/ Other oc pancy (2) (3) (5),(6) showers facilities A- Assembly Male: l: 1-100 Male: I: 1-250 1 service (OL door activities 1:1-100 2:101-200 I:1-200 _ 2:251-500 sink or or Portin 2:101-200 3:201-400 2:201-400 3:501-750 laundrytr 7— L eve is)- 3:201400 4:401-600 3:401-750 am 3ement parks, Female: Over 600, Females: ble hers, 1:1-25 add (1) 1:1-100 Over 750.add (1) gr stands and 2: 26-50 fixture for 2: 101-200 fixture for each stac ums. 3:51-100 each 4:201-300 additional 500 4:101-200 additional 5:301-500 persons. 6: 201-300 300 males. 6: 501-750 8: 301-400 Over 750, add Over 400, add (1) fixture for (1) fixture for each additional each additional 250 males and 500 males and (1) fixture for (1) fixture for each additional each additional 200 females. 125 females. B- 3usiness Male: l: 1-100 Male: _ I per 150 1 service (o ce, 1:1-50 2:101-200 1:1-75 sink or pro ssional or 2: 51- 100 3: 201-400 2: 76-150 laundry se ce type 3: 101-200 4:401-600 3: 151-200 tra actions)- 4:201-400 4:201-300 b s, vet clinics, Female: Over 600, 5: 301400 hos itals, car l: 1-15 add (1) Female: wa i, beauty 2: 16-30 fixture for l: 1-50 salons, 3:31-50 each 2:51-100 am ulatory health 4: 51-100 additional 3: 101-150 , car facilities, 8:101-200 300 males. 4: 151-200 lau dries and dry 11: 201400 5: 201-300 cle ing-, 6:301-400 edt cational Over 400, add occ panties (1) fixture for Over 400 add (ab ve the 12'" each additional (1) fixture for gra e), or training 500 males and each additional fac ities not (1) fixture for 250 males and lot ted within each additional 91) fixture for sch 101, post 150 females. each additional o es, printing 200 females. sh s. E- ducational - Male: 1 per 100 Male: _ 1 per 150 1 service pri to or public I per 50 1 per 40 sink or sch iol Female: Female: laundry in I per 30 1 per 40 Tp a of Water Closets Urinals (4) Lavatories Bathtubs or Drinking Other occ pancv(2)3) (5),(6) showers fountains/Facilities Fl IF2 Factory Male: Male: I shower for l: 1-250 1 service or Industrial - 1: 1-50 _ 1: 1-50 each 15 2: 251-500 sink or fab licatingor 2:51-75 2:51-75 persons 3:501-750 lauhdry ass Imbly work 3: 76-100 3: 76-100 exposed to Female: Female: excessive Over 750. add (1) 1: 1-50 1: 1-50 heat or to fixture for each 2:51-75 2:51-75 skin additional 500 3:76-100 3:76-100 contaminati on with persons. Over 100, add Over 100, add poisonous, (1) fixture for (I) fixture for infectious or each additional each additional irritating 40 persons. 40 persons. material 1-1 nstitutional Male: Male: I per 8 1 per 150 1 service (ho ses more than 1 per 15 _ 1 per 15 sink or 16 ersons on a laundry tr 24- our basis)- Female: Female: sub tance abuse 1per 15 1 per 15 cen rs, assisted livi g, group hot es, or res ential fac ities 1-2 nstitutional - Hospitals and Hospitals and Hospitals Hospitals and nursing I service homes- individual me ical, nursing homes- _ nursing homes- and nursing sink or individual individual homes- ps} hiatric, and ward rooms: laundry tr sur ical or rooms and ward rooms and ward individual 1 per 150 room: rooms: nor ing homes, and ward fos r care 1 per room rooms: fac ities, (individual I per room det xification room) (individual Iper room Hospital waiting or visitor rooms: fac ities room) (individual I per 8 1 per 10 patients rooms) 1 per room patients(ward (ward room) I per 20 room) patients Hospital waiting (ward room) or visitor Hospital waiting or rooms: visitor rooms: 1 per room 1 per room. Employee use: Male: _ Employee use: I per 40 Male: Female: 1: 1-15 1 per 40 2: 16-35 Over 55, add (1) 3: 36-55 fixture for each Female: additional 40 1: 1-15 persons. 3: 16-35 4: 36-55 Ty a of Water Closets Urinals (4) Lavatories Bathtubs or Drinking Other Octpancy (2) (3) (5)1(6) showers fountains/Facilities 1-3 lInstitutional Prisons: Prisons: Prisons: Prisons: Correctio I fac juvenileilities 3 3 ses more than 3 le)- 1 per cell _ I per cell 1 per 20 1 per cell block/floor con -ction centers, Correctional Correctional Correctional Correctional facilities centers: facilities or or juvenile center: det tion centers, facilities or facilities or 1 service jail refc matories juvenile center: juvenile center:uvI enile centers: 1 per floor sink or laundry tr 1 per 8 1 per 10 Employee use: 1 per 8 Employee use: Male: Employee use: _ I per 150 Male: 1: 1-15 2: 16-35 1 per 40 3: 36-55 Female: Female: I per 40 1; 1-15 3: 16-35 4: 36-55 Over 55, add (1) fixture for each additional 40 persons. 1-4 nstitutional Male: Male: _ I per 150 1 service (m re than 5 I: 1-I5 _ 1 per 40 sink or per ns of any age 2: 16-35 laundry in tha receives care 3: 36S5 Female: for ss than 24 1 per 40 ho s)- adult day caq, child day Female: car 1: 1-15 3: 16-35 4: 36-55 Over 55, add (1) fixture for each additional 40 2ersons. M- Niercantile Male: 0: 1-200 Male: _ 1: 1-250 1 service (th sale of 1:1-100 1:200-400 1:1-200 2:251-500 sink or me handise and 2:101-200 2:201-400 3:501-750 laundry it is put cessible to the ic)- 3: 201400 Female: Over 400, add (1) Female: 1: 1-200 Over 750, add (1) def utrnent stores, 1: 1-100 fixture for 2: 201-300 fixture for each d stores, 2:101-200 each 3:301-400 additional 500 ma ets, retail 4: 201-300 additional persons. sto s 6: 301400 500 males. Over 400, add Over 400, add (1) fixture for (1) fixture for each additional each additional 500 males and 500 males and (1) fixture for (1) fixture for each additional each additional 400 females. 200 females. Ty a of Water closets Urinals (4) Lavatories Bathtubs or Drinking Other oci ipancy 2 3) (5),(6) showers fountains/facilities R- Residential 1 per sleeping 1 per sleeping 1 per _ 1 service (millimurn ho stay)- Is, motels, room _ room sleeping room sink or laundry tr , 1 bed nd breakfast R-2 Residential Dormitories: Dormitories: Dormitories: Dormitories: Dormitories: Dormitori : I per 25 I per 8 (]or term or Male: Male: 1 per 150 1 service pen apa ument)- orient houses, 1 per 10 Female: Over 150 1 per 12 Female: Apartment sink or laundry tr boa ding houses I per add (1) l perl2 houses/units I per (no transient), fixture for Ajoartment houses/uni I kitchen con dor ents, itories, Add(1)fixture for each each additional 50 Add(1)fixture for each apartment fiat mities. additional 25 males. additional 20 sink per sor, vac ities, tion males and (1) fixture for each males and (1) fixture for each apartment. laundry tr 1 tim share additional 20 additional 15 or I pro erties females. females. automatic clothes Employee use: Employee use: washer Male: Male: connectio 1: 1-15 1 per 40 per unit or 2: 16-35 Female: laundry tr 3: 36-55 l per 40 Female: Apartment or 1 1: 1-15 house/unit: automatic 3: 16-35 4: 36-55 1 per apartment clothes washer connectio Over 55, add for each I (1) fixture for units. each additional 40 persons. Apartment House/Unit: 1 perapartment R- Residential Male: Male: 1 per 8 1 per 150 1 service (101 g term or 1:10 _ 1 per 12 sink or per anent in Female: Female: laundry tr v nat re)- Buildings I per 8 1 per 12 wit not more tha 2 dwelling un' s, care Add (1) fixture Add (1) fixture fac lities that for each for each pr ,ide additional 25 additional 20 ac mmodations males and (1) males and (1) for 5 or fewer fixture for each fixture for each pe ons additional 20 additional 15 females. females. Ty a of Water closets Urinals (4) Lavatories Bathtubs or Drinking Other oe pancy(2) (3) (5),(6) showers fountains/facilities R- Residential 1 per one and I per one and 1 per one _ 1 kitchen (or and two two familv _ two family and two sink and fain ly dwelling) dwelling dwelling family automatic dwelling clothes washer connection per one an two family dwelling R-4 Residential Male: Male: I per 8 1 per 150 1 service (res dential care 1 per 10 _ 1 per 12 sink or or sisted living Female: Female: laundry tr for nore than 5 1 per 8 1 per 12 but of more than 16 1 ersons)- Add (1) fixture Add (1) fixture assi ted living for each for each fac ties, group additional 20 additional 20 ho s, halfway females. males and (1) ho es fixture for each additional 15 females. SI, 2 Storage- Male: Male: 1: 1-250 1 service stonageofgoods, 1:1-100 1:1-200 2:251-500 sink or Nvai house, 2:101-200 2:201-400 3:501-750 laundry aird aft hanger, 3: 201-400 3: 401-750 foo products, Female: Female: Over 750, add (1) apr 1 iances I: 1-100 1: 1-200 fixture for each 2: 101-200 2: 201400 additional 500 3: 201-400 3: 401-750 persons. Over 400, add Over 750 add (1) fixture for (1) fixture for each additional each additional 500 persons. 500 males and (1) fixture for each additional 150 females. Notes: 1. The figures shown are based upon one fixture being the minimum required for the number of persons indicated or any fraction thereof. 2. A restaurant is defined as a business that sells food to be consumed on the premises. a. The number of occupants for a drive-in restaurant shall be considered as equal to the number of parking stalls. b. The hand -washing facilities shall be available in the kitchen for employees. 3. The total number of required water closets for females shall not be less than the total number of required water closets and urinals for males. 4. For each urinal added in excess of the minimum required, one water closet shall be permitted to be deducted. The number of water closets shall not be reduced to less than two-thirds (2/3) of the minimum requirement. 5. Group lavatories that are 24 lineal inches (610mm) of wash sink or 18 inches (457mm) of a circular basin, where provided with water outlets for such space, shall be considered equivalent to one lavatory. 6. Metering or self-closing faucets shall be installed on lavatories intended to serve the transient public. • The occupant load for all buildings shall be determined by Section 1004 of the International Building Code. Section 10. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article I. Division 3 to be numbered 8-1-3-418.3 which section reads as follows: Sec. 8-1-3-418.3 Amendment to Section 418.3 of the UPC. Section 418.3 of the UPC is amended to read as follows: Sec. 418.3 Location of Floor Drains. Floor drains shall be installed in the following areas: a. Toilet rooms containing one (1) or more water closets or a combination of one or w more lavatories, one (1) water closet and one (1) urinal, except in a dwelling unit. O N b. Commercial kitchens and in accordance with Section 704.3. - c. Laundry rooms in commercial buildings and common laundry facilities in multi- family dwelling buildings. 0 U Section 11. New Section. The Salina Code is amended by adding a new section to Chapter 8. Article 1. Division 3 to be numbered 8-1-3-603.4.2 which section reads as follows: Sec. 8-1-3-603.4.2 Amendment to Section 603.4.2 of the UPC. Section 603.4.2 of the UPC is amended to read as follows: Sec. 603.4.2 Testing. The premise owner or responsible person shall have the backflow prevention assembly tested by a certified backflow assembly tester at the time of installation, repair, or relocation and tested and overhauled on the schedule listed in Salina Code Chapter 41, Article II, Division 4 - Cross Connections. The periodic testing shall be performed in accordance with the procedures referenced in Table 1401.1, 14-1, by a tester qualified in accordance with those standards. Section 12. New Section. The Salina Code is amended by adding a new section to Chapter 8, Article I. Division 3 to be numbered 8-1-3-709.0 which section reads as follows: Sec. 8-1-3-709.0 Amendment to Section 709.0 of the UPC. Section 709.0 of the UPC is amended to read as follows: Sec. 709.0 Gravity Drainage Required. Wherever practicable, all plumbing fixtures shall be drained to the public sewer or private sewage disposal system by gravity. Where it is determined by the authority having jurisdiction that gravity drainage for an alteration is impractical, drainage piping serving such plumbing fixtures shall meet the requirements of Section 710.0. Exception: Upon prior approval by the authority having jrisdiction, low flow fixtures such as but not limited to bar sinks. hand sinks, and indirect waste receptors for drink stations may drain into an approved, self-contained water removal system. Section 13. New Section. The Salina Code is amended by adding a new section to Chapter 8. Article I, Division 3 to be numbered 8-1-3-807.4 which section reads as follows: Sec. 8-1-3-807.4 Amendment to Section 807.4 of the UPC. Section 807.4 of the UPC is amended to read as follows: Sec. 807.4 Domestic Dishwashing Machine. Deleted. Section 14. Repealer. Existing Salina Code Sections 8-71 through 8-118 are repealed. Section 15. Effective. That this ordinance shall be in full force on January 1, 2017 after its adoption and publication once in the official city newspaper by the following summary: w II Ordinance No. 16- 10848 Summary On October 3. 2016 the City Commission passed Ordinance No. 16- 10848. The Ordinance amends Chapter 8, Article I, Division 3 of the Salina Code: repeals existing sections 8-71 through 8-118: adopts and incorporates the 2012 edition of the Uniform Plumbing Code by reference: and adopts local amendments with an effective date of January 1, 2017. A complete copy of the ordinance can be found at xvwxv.salina-ks.gov or in the office of the City Clerk, 300 W Ash Street, free of charge. This summary is certified by the City's legal counsel. [SEAL] ATTEST: 3h .Wicks, C�Mr/C�, City Clerk Introduced: August 22. 2016 Passed: October 3. 2016 Certification of Publication Summary: yrBengtson, a_ f]