Loading...
02-10087 Amend UBC UPC(Published in the Salina Journal on July 4 2002) ORDINANCE NUMBER 02-10087 AN ORDINANCE PROVIDING FOR AMENDMENT TO CHAPTER 22, SECTION 22-23 PERTAINING TO PARK SERVICE DISTRIBUTION SYSTEMS AND CHAPTER 8, SECTIONS 8-36.1, 8-188.1 AND 8-401 PERTAINING TO THE ADOPTION OF A LOCAL AMENDMENTS TO THE 1997 UNIFORM BUILDING CODE AND 1997 UNIFORM PLUMBING CODE, AND PERMITS REQUIRED. BE IT ORDAINED by the Governing Body of the City of Salina, Kansas: Section 1. That Section 22-23 of Chapter 22 of the Salina Code are hereby amended to read as follows: "Sec. 22-23. Park service distribution systems. (a) Gas distribution system. The gas distribution system in the mobile home park shall meet all the requirements of this Code. When liquefied petroleum gas is used, the provisions of the "Rules and Regulations Relating to the Liquefied Petroleum Gas Industry of the State of Kansas" as adopted by this Code shall apply. (1) Gas service systems shall be inspected by the building official prior to release of service. (2) Connection of a gas line to the mobile home shall be by a flexible connector bearing the seal of the American Gas Association. (3) An iron -bodied, brass core cock with provisions for locking in closed position shall be installed on the riser as close as practicable to the point of emergence from the ground, and the riser shall be protected by a solid post set in the ground adjacent to the riser pipe. (4) An approved automatic gas safety regulation device shall be installed in the service line or an automatic shut-off with plastic nipple shall be installed directly above the core cock. (5) Gas meters shall be removed upon discontinuance of service by gas service company. Slugging of meters is prohibited. (b) Park water distribution systems. The water distribution system in the mobile home park shall meet all the requirements of this Code and the state board of health. The size and location of all water mains shall be approved by the city engineer. (c) Electrical distribution system. The electrical distribution system in the mobile home park shall meet all the requirements of this Code. (1) Electrical service systems shall be inspected by the building official prior to release of service. (2) A minimum of one hundred (100) amperes service will be required at each new mobile home stand (two (2) fifty (50) amperes mains within the park service panel). (3) No splices shall be allowed in any mobile home power supply cord. (4) Electrical meters shall be removed upon discontinuance of service by electrical service company. Slugging of meters is prohibited. ConsGiEeIMSNIre (d) Sanitary sewer system. Individual sewer connections shallbe provided for each mobile home space in the park and shall meet all the requirements of this Code and the state board of health. The size and location of all sewer mains shall be approved by the city engineer. (e) Fire protection. Within each mobile home park there shall be provided a fire protection system approved by the fire chief in accordance with the Mobile Home Park Fire Safety Code of the National Fire Protection Association (NFPA)." Section 2. That Sections 8-36.1, 8-188.1 and 8-401 of Chapter 8 of the Salina Code are hereby amended to read as follows: "8-36.1. Amendment of Section 106.2 of the Uniform Building Code. [Section 106.2 of the Uniform Building Code is amended to read as 'follows:] 106.2 Work Exempt from Permit. A building permit shall not be required for the following: 1. One-story detached accessory buildings used as tool and storage sheds, playhouses, and similar uses, provided the floor area does not exceed 120 square feet (11.15 m2). 2. Fences not over six (6) feet (1829 mm) high. 3. Oil derricks. 4. Movable cases, movable counters and movable partitions not over 5 feet 9 inches (1753 mm) high. 5. Retaining walls that are not over 4 feet (1219 mm) in height measured from the bottom of the footing to the top of the wall, unless supporting a surcharge or impounding Class I, II or III -A liquids. 6. Water tanks supported directly upon grade if the capacity does not exceed 5,000 gallons (18 927 L) and the ratio of height to diameter or width does not exceed 2:1. 7. Platforms, uncovered decks, walks and driveways not more than 30 inches (762 mm) above grade and not over any basement or story below. 8. Painting, papering and similar finish work. 9. Temporary motion picture, television and theater stage sets and scenery. 10. Window awnings supported by an exterior wall of Group R, Division 3, and Group U Occupancies when projecting not more than 54 inches (1372 mm). 11. Prefabricated swimming pools accessory to a Group R, Division 3 Occupancy with the capacity for not more than two feet of water. 12. Roof coverings not involving structural components. 13. Installation of replacement windows not requiring wall or structural changes, however the lack of a requirement for a permit does not allow the installation of windows smaller than required for light, ventilation or egress. ComoliW sd. 14. Installation of exterior siding. Unless otherwise exempted, separate plumbing, electrical and mechanical permits will be required for the above -exempted items. Exemption from the permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction. 8-188.1. Amendments to Chapter 12 — Fuel Piping of the Uniform Plumbing Code. 1211.0 Installation of Gas Piping 1210.1 All pipe used for the installation, extension, alteration, or repair of any gas piping shall be standard weight wrought iron or steel (galvanized or black) or yellow brass (containing not more than seventy-five (75) percent cooper). Corrugated Stainless Steel Tubing (CSST) systems may be used when installed according to the manufacturers installation instructions by installers certified by the manufacturer. Approved PE pipe may be used in exterior buried piping systems. 1211.3 No gas piping shall be installed in or on the ground under any building or structure unless installed in gastight conduit, and all exposed gas piping shall be kept at least six (6) inches (152 mm) above grade or structure. The term "building or structure" shall include structures such as porches and steps, whether covered or uncovered, breezeways, roofed porte-cocheres, roofed patios, carports, covered walks, covered driveways, and similar structures or appurtenances. The conduit shall be of material approved for installation underground beneath buildings and not less than Schedule 40 pipe. The interior diameter of the conduit shall be not less than one-half (%2) inch (12.7 mm) larger than the outside diameter of the gas piping. The conduit shall extend to a point at least (12) inches (305 mm) beyond any area where it is required to be installed or to the outside wall of a building, and the outer ends shall not be sealed. Where the conduit terminated within a building, it shall be readily accessible and the space between the conduit and the gas piping shall be sealed to prevent leakage of gas into the building. Concealed unprotected gas piping may be installed above grad in approved recesses or channels. Exception: When necessary due to structural conditions, approved type gas piping may be installed in other location, when permission has first been obtained from the Administrative Authority. Piping shall not be installed in or through a circulating air plenum or duct, clothes chute, chimney or gas vent, ventilating duct, dumbwaiter, or elevator shaft. 8-401. Permit. No person shall install any fence or wall without first having procured a written permit therefor from the building official. The city clerk shall charge a fee as prescribed in section 2-2. Exception: Permits are not required for fences that are not over six (6) feet (1829 mm) high." Section 3. That the existing Sections 8-36.1, 8-188.1, 8-401 and 22-23 of the Salina Code are hereby repealed. Section 4. That this ordinance shall be in full force and effect from and after its adoption and publication once in the official city newspaper. [SEAL] ATTEST: Xj&-V� Lieu Ann Nicola, City Clerk Introduced: July 1, 2002 Passed: July 8, 2002 estin M. Seat n, Mayor