sewer ext. permit 7/25/1986State of Kansas ' DIVISION OF ENVIRONMENT APPLICATION FOR SEWER EXTENSION PERMIT of Selina, Kansas hereby makes application for a permit Municipality, Public Sewer District or Person) to extend its system of sanitary sewers served by a wastewater treatment facility now operating under Kansas Water Pollution Control Permit No. M-SN33-1001 effective July 25 &S-0038-474 19 8f; in the manner indicated by the plans, specifications, and other data attached hereto. Any municipality, township, county, or legally constituted sewer district, etc., wishing to extend its sanitary sewer system is required by K.S.A. 65-165 and K.S.A. 65-166 to submit an extension for review by the Division of Environment. Plans and specifications submitted must comply with Division of Environment's"Minimum Standards of Desion for Water Pollution ntroi raciiities% 1: What are the conditions and capacity of the existing receiving sewer system: a. Do surcharge or bypass conditions exist in the receiving sewer line(s)? No If so, what is the location(s)? b. What steps are being taken to eliminate the conditions identified in 1:a.? N/A C. Do bypass conditions exist at downstream receiving pump stations? N/A If to, what is the location? d. What steps are being taken to eliminate the conditions identified in l.c.? N/A e. Are combined sewers used for transporting wastewater flows to the treatment facil- ity? No 2. Please provide the following information concerning the waste treatment facility which will.receive the flow from the proposed extension: a. What -is the present average daily flow at the facility? • 4.0 mgd b. Does the facility have a bypass? Yes , Type Bypass Line , Estimated frequency of bypass None Estimated volume of bypass None 3. What is the legal name of the addition, subdivision, benefit district, etc., which will be directly served by the sewer extension? Meadowlark Acres Addition No. 3 and the Central Mall 4. What.is the name and certificate number of the certified operator and the name of the legal Jurisdiction which will treat the wastes? Certificate"No. 2392, George Pauls, Ch�Ooerator City of Salina Kansas _ 5. What are the lengths and ,sizes of the sewer line to be built? 8" FM - 3050 L.F. �.• . How many manholes and clean -outs will be built? 0 - Manholes; 0 - Cleanouts 7. 'If wastewater pumpingfaciii,ties'are included in the project provide the following informa- tion y 450 gpm @ Dry Pit Vertical .-- a. Number of Pumps -36 fe— r- '2 b. Capacity and Head c. Type Sewage Pumps d.•. Method of ContTv ubller System e. Type of A4arm None f. Control Elevations: ZMAI d6Yp@UM 1215.50,High Level On 1217.00,Alarm None Pumps Off 1213:00 One Pump ltao Pumps g. Type of alternative power or.bypass prevention provided? N/A. 8. Are any of the proposed sever lines or other facilities within a floodplain? Yes Are any new service connections located in a floodplain? Yes .9. Provide the following information concerning the estimated .use of the proposed extension: a. Per capita. design flow 250 apd. b.. Capita per single family dwelling unit 1 gpm Capita per multi -family dwelling unit 3 wpm c. Probable number of single family'dwellings connected first year 0 maximum number , 60 , in what time span 15 yrs. d. Probable number of multi -family dwellings connected first year 0 maximum number 10 in what time span_ 15 yrs. • (Central e. . Probable number of office or light commercial units connected first year 1 Mall) *What overall flow is expected the first year 175 gpm What is the maximum number which may be connected and in what time span 11 - 15 Years What is the maximum flow expected 365 .gpm . f. Probable number of commercial and industrial plants to be connected 0 Please specify for each plant the estimated flow (gpd), pounds of BOD$ per day, major activity, estimated number of employees and number of shifts (attach separate sheet on these items). 10. Give the name of the firm repsonsible for engineering Wilson & Company, Engineers & Architects 11. Uho will provide full time engineering observation of the constructi 12. The information contained above is accurate to the best of my knowledge. (Signed) Registered Professional Engineer Failing Address' Wilson & Company, Engineers & Architects PO -Box 1640, Salina, IS 67402-1640 In making application for a sewer extension permit, I hereby certify that continuous engineering observation of the construction of the proposed improvements, including building connections, shall be provided in accordance with Kansas Department of Health and Environment Regulation 28-16-55. Title: Ifr«"� P.ailing Address: 8a'>< 73G 1C,4A 67Wt— Division of Environment Bureau of Water Protection Forbes. Field, Bldg. 740 Topeka, Kansas 66620 ATTN: Municipal Programs Section Re: Sewer Extension Gentlemen: This letter will serve to notify your office that the above referenced project was constructed in accordance with the approved plans and specifi- cations. The project was approved by your office under Sewer Extension Permit No. , issued Sincerely yours, cc: