fema flood study bucher willis ratliff 3/13/1985DEAN BOYER. P. E. CITY ENGINEER ENGINEERING DEPARTMENT .300 WEST ASH STREET P. O. BOX 746 SAUNA, KANSAS 67401 AREA CODE 913 527-9451 March 13, 1985 Mr. Thomas Darnell Development Consultants, Inc. 327 South Fifth Street Salina, Kansas 67401 Re: FEMA Design Criteria Dear Mr. Darnell: DONALD E. HOFF. P. E. ASST. CITY ENGINEER D. W. BASSETT TRAFFIC ENGINEER In reviewing the data furnished our office by Bucher, Willis & Ratliff, Consulting Engineers, who performed the hydrologic analysis for the FEMA Flood Study for Salina, the following listed design assumptions were utilized in this study: (a) Runoff was based on the maximum 24 hr. storm (100 yr. & 500 yr. frequency). (b) Rivers and streams were at high stages which prevented gravity flow at the storage outlets. (c) Underseepage at the flood control dikes diminished the available storage volumes of the ponding areas. (d) The design rainfall (100 yr. or 500 yr. frequency) occurred after prior rainfall has saturated the soil within the drainage basin. (e) The pumps at the ponding areas are not operating. (f) A volume of runoff (100 yr. or 500 yr. frequency) was assumed to equal the inches of direct runoff times the drainage area of the basin. If you need any additional information concerning the above referenced flood study, please contact me. Sincerely, MEMBER ... KANSAS LEAGUE.OF MUNICIPALITIES - NATIONAL LEAGUE OF CITIES Don Hoff, MEMBER ... KANSAS LEAGUE.OF MUNICIPALITIES - NATIONAL LEAGUE OF CITIES